Line 19: Line 19:
Optionally you can allow IP based exceptions from the rules
Optionally you can allow IP based exceptions from the rules
* Set '''passcodeTrustedIp''' to true [[ServerSettingSingle.do?DataType=1&PolicyName=passcodeTrustedIp | link]]
* Set '''passcodeTrustedIp''' to true [[ServerSettingSingle.do?DataType=1&PolicyName=passcodeTrustedIp | link]]
* Set '''passcodeTrustedIpList''' to contain your office IP's: ServerSettingSingle.do?DataType=3&PolicyName=passcodeTrustedIpList
* Set '''passcodeTrustedIpList''' to contain your office IP's  [[ServerSettingSingle.do?DataType=3&PolicyName=passcodeTrustedIpList | link]]


Furthermore you can allow multiple logins from the same IP to  
Furthermore you can allow multiple logins from the same IP to  
* Set '''passcodeUserIpHistory''' to trueServerSettingSingle.do?DataType=1&PolicyName=passcodeUserIpHistory
* Set '''passcodeUserIpHistory''' to true [[ServerSettingSingle.do?DataType=1&PolicyName=passcodeUserIpHistory | link]]
* Set '''passcodeUserIpHistoryCount''' to minimum succesfull loginsServerSettingSingle.do?DataType=2&PolicyName=passcodeUserIpHistoryCount
* Set '''passcodeUserIpHistoryCount''' to minimum succesfull logins [[ServerSettingSingle.do?DataType=2&PolicyName=passcodeUserIpHistoryCount | link]]





Revision as of 20:11, 9 November 2017

This article will be published 13 november 2017

Preparation

To enable 2 factor authentication for users you will need to prepare the following:

  • List of IP's that should not require 2 factor authentication
  • An messaging URL for sending SMS's
  • Access to cellphone numbers for all employees


Setup

First you will setup the system to run in testmode, so that all messages are sent for you. After checking everything works, disable the testmode.

Change server configurations

  • Set smsConnectUrl to your connection URL
  • Check that smsParamMessage fits the parameter name of your SMS provider
  • Check that smsParamNumber fits the parameter name of your SMS provider

Optionally you can allow IP based exceptions from the rules

  • Set passcodeTrustedIp to true link
  • Set passcodeTrustedIpList to contain your office IP's link

Furthermore you can allow multiple logins from the same IP to

  • Set passcodeUserIpHistory to true link
  • Set passcodeUserIpHistoryCount to minimum succesfull logins link


Stop the application server

Go to the application folder and dive into: <application>\WEB-INF\web.xml

Uncomment the section containg the servlet mapping

   <filter>
       <filter-name>TwoFactorAuthentication</filter-name>
       <filter-class>dk.tempusserva.passcode.SmsVerificationFilter</filter-class>
   </filter>
   <filter-mapping>
       <filter-name>TwoFactorAuthentication</filter-name>
       <url-pattern>/main</url-pattern>
   </filter-mapping>

Start the application server

Test and go live

Change server configurations

  • Set "smsTestMode" to true